Neonatal Equipment

Math Lab
Neonatal Equipment

Showing all 8 results

    NEONATAL INTENSIVE CARE INCUBATOR
    Product Code - KS000586

    The Neonatal Intensive Care Incubator has been specially designed to proved the safest and most stable en....

    Add To Enquiry Download Catalogue View Detail

    Description & Specification

    NEONATAL INTENSIVE CARE INCUBATOR

    The Neonatal Intensive Care Incubator has been specially designed to proved the safest and most stable environment for the critical neonate. With a wide range of accessories, it can be tailored to meet any situation arising in th care of the infant.The excellent nursing facilities, safe and reliable operation, ease of cleaning and sturdy construction of the KEM 100 make it a vital part of the equipment in the hospital.

    NEONATAL INTENSIVE CARE INCUBATOR
    Product Code - KS000587

    We offer you the best quality {NEONATAL INTENSIVE CARE INCUBATOR} with the most accurate specifications a....

    Add To Enquiry Download Catalogue View Detail

    Description & Specification

    NEONATAL INTENSIVE CARE INCUBATOR

    We offer you the best quality {NEONATAL INTENSIVE CARE INCUBATOR} with the most accurate specifications as given below. Click on the View Details button to check out the specifications of our product. In case of any product enquiry do feel free to send us an email

    Technical Specifications:

      • Canopy : 900x450x430mm
      • Mattress : 525x380mm
      • Height : 1425mm
      • Depth : 585mm
      • Width : 945mm
      • Baby Tray : Fixed tray with Mattress
      • Castors : 125mm diameter, with brakes

    Recommended Environmental Specifications

      • Warm-up time to 37°C : 20 min @ 20 °C
      • Ambient temperature control : 28 °C to 39 °C, 0.5 °C incrmt.
      • Skin temperature : 35 °C to 38 °C, 0.5 °C incrmt.
      • Noise level inside Canopy :
      • Air velocity over bed :
      • Air filter capacity : 99% (for 0.5um)
      • Air and skin temp. sensor accuracy : +/- 0.1 °C

    Salient Features:The Electrical Controller:

    • – The Controller based on Micro computerized systems.
    • – Large bright display for easy monitor and for viewing from a distance.
    • – Digital display system provided to measure the Infant temperature, Air Temperature and to set the required temperature.
    • – Feather touch keys provided for easy for easy operation.
    • – Bar graph LED system to indicate the heater output.

    Fault Indications with Alarm for-For skin and air temperature too low or high, fan failure, heater failure, power failure, skin and air probe failure, canopy open, temperature >39°C in any mode, control module open and circuit fault.Baby Probe / Air Probe:Baby probe / Air probe is made of highly sensitive sensor and interchangeable, field calibrationstaken care of by software. The probe is made up of silicon sheathed cable, which allows easycleaning.

    • Other Facilities:
    • – IV Stand Provided
    • – Front panel with large door and 2 port holes.
    • – Rear: 2 port holes and 4 holes for tubes
    • – Combined window rotation and closing system
    • – Stand with integrated base cabinet.
    • – Three Storage drawers
    • – Transfer handle
    • – Guard rail and support
    • – Fitted with support for O2 cylinder
    • – Platform for use with monitor or pulse oximeter (Optional)

    NEONATAL PHOTOTHERAPY UNIT CFL
    Product Code - KS000588

    Phototherapy system for treatment of neonatal hyperbilirubinaemia.It is powered by a six-CFL module provi....

    Add To Enquiry Download Catalogue View Detail

    Description & Specification

    NEONATAL PHOTOTHERAPY UNIT CFL

    Phototherapy system for treatment of neonatal hyperbilirubinaemia.It is powered by a six-CFL module providing intense blue light. Unwanted heat is filtered and eliminated.

    NEONATAL PHOTOTHERAPY UNIT CFL-A
    Product Code - KS000589

    FEATURES:CFL module For the first time in the world, six lamps are used for speedy and e....

    Add To Enquiry Download Catalogue View Detail

    Description & Specification

    NEONATAL PHOTOTHERAPY UNIT CFL-A

    FEATURES:CFL module For the first time in the world, six lamps are used for speedy and effective treatment. The CFL’s provide blue light at ~18 μW/cm 2/nm. CFLs last five times longer than ordinary tube lights, requiring less frequent replacement. The CFL comes optionally with four blue and two white lamps for examination of the infant.Focused blue lightLight from the CFL module is focused on the baby bed, avoiding scatter into the care-provider space.Heat dissipationSpecial vents are provided on the light unit to divert heat, avoiding undesirable warming of body.Compatibility with other equipmentThe tiltable light unit may be placed over any bed or incubator and in combination with a radiant warmer or another CFL unit for additional intensity. The height of the unit is adjustable, so that it is suitable for different bed heights. The T-Shaped base slides conveniently out of the way under other equipment.AccessoryThe CFL is provided with separately operated white lights. A chronometer is provided to monitor lamp usage. An additional chronometer may be used for management of treatment.

    NEONATAL RADIANT WARMER
    Product Code - KS000590

    Provides radiant warmth for infants suffering from sever heat loss. It is suitable for all environments f....

    Add To Enquiry Download Catalogue View Detail

    Description & Specification

    NEONATAL RADIANT WARMER

    Provides radiant warmth for infants suffering from sever heat loss. It is suitable for all environments from labor to neonatal ICU

    NEONATAL RADIANT WARMER-A
    Product Code - KS000591

    FEATURES:* IR radiation is beamed from a quartz heater by a parabolic reflector. This provides focused wa....

    Add To Enquiry Download Catalogue View Detail

    Description & Specification

    NEONATAL RADIANT WARMER-A

    FEATURES:* IR radiation is beamed from a quartz heater by a parabolic reflector. This provides focused warmth rapidly on the desired area.* The height of the IR unit may be adjusted for different bed heights. The low T-shaped base slides out of the way under other equipment.* Infant temperature is measured quickly by a high sensitivity thermistor probe and displayed on a large, easy-to-read LED display. The control panel is ergonomically designed with soft-touch keys.- The NWS is equipped with dazzle-free observation light for examination of the infant.

    RESUSCITATION SYSTEM
    Product Code - KS000592

    We believe that a warmer design should take into account both the science and art of the thermal regulati....

    Add To Enquiry Download Catalogue View Detail

    Description & Specification

    RESUSCITATION SYSTEM

    We believe that a warmer design should take into account both the science and art of the thermal regulation. To provide the most efficient use of heat we select the appropriate wattage, use the best material for heating element and design the reflectors for maximum effectiveness. The art involves designing the unit for optimum functionality. It is an equation we have worked hard to perfect.Neonatal resuscitation units are commonly used as open care incubator in the delivery rooms, Intensive care units & operation theaters. They must combine heat control, Resuscitation, Phototherapy unit, space for monitoring systems and complete accessibility to the infant with an optimum medical procedural capability.THE ELECTRONIC CONTROLLER:* The controller is based on micro computerized system.* Large bright displays are easy to monitor & for viewing from a distance.* Double digital display system provided to measure the infant temperature and to set the required temperature.* Feather touch keys provided for easy operation.* Bar graph LED system provided to indicate the heater output.* Temperature measured in °C* Manual control system provided.* Fault indication with alarms for Baby probe failure, 1°C temperature high, 1°C temperature low.* High temperature cut-off & Power failure.BABY PROBE: Baby probe is made of highly sensitive sensor. The probe is interchangeable & field calibration taken care of by software. The probe is made up of silicon sheathed cable, which allows easy cleaning.THERMAL CARE: Special CE approved 750W ceramic heater is used to ensure fail safe heating and to provide maximum effectiveness. The chance of breakage of the heater is minimum. The heater can be easily cleaned. To ensure proper heating of the mattress. we match our ceramic heating element to the size of the warmer bed. Our specially designed parabolic reflector focuses the heat, minimize scatter and achieves superior thermal performance.APGAR TIMER: The Digital Apgar timer is switched on at the moment of birth of the baby and an acoustic alarm will sound after 1.5, 10, 15 and 20 minutes, remainding to examine the new born according to the Apgar scheme.PATIENT BED: The large patient bed is adjustable to trendelenburg and fowler position. The Acrylic sidewalls can be positioned upward or downward.X-RAY CASSETTE TRAY: The Neonatal Resuscitation Unit heater box swivels away from bed to make room for an X-ray unit. Convenient tray assists you to achieve accurate X-rays without disturbing the infant.OBSERVATION LAMP: A Halogen based observation light facilitates to focus the light on any area of the bed. RESUSCITATOR (OPTIONAL): Neonatal Resuscitation allows the resuscitation of the distressed newborns in delivery room or in case of emergency. Reanimation is preformed with positive pressure to the mask or endotracheal tube with manual control and free expiration. The minimum and maximum pressure values can be preset and are clearly indicated on the manometer. The Resuscitation operates when connected to the air-oxygen mixer or through any other flow meter.ELECTRICAL SLOW SUCTION (OPTIONAL): The slow suction unit is designed to work on latest diaphragm technology and results in being maintenance free and provides high performance. This vacuum level can be adjusted with the regulator. A vacuum gauge is provided to monitor the pressure. The suction collection jar is unbreakable and it can be easily removed and sterilized.PHOTOTHERAPY UNIT (OPTIONAL): A halogen based phototherapy unit provided for hyperbilirubinaemia management. Three halogen lamps are fitted on either side of the overhead heater box. It is fitted in an angled position to focus the radiation on the Infant for maximum effectiveness.BABY WEIGHING SCALE (OPTIONAL): A built in digital weighing scale allows you to measure the weight without disturbing the infant.PHYSICAL PARAMETERS:Mattress : 780 mmLength: 490 mmWidth: 50 mmThickness: 920 mmWorking level from ground : 920 mmMaxium baby tray tilt on both sides continuously variable} : +/-8°Weight: 130 kgCastors: 100 mm with 2 brake wheels and 2 non-brake wheelsENVIRONMENTAL SPECIALTIONS:Operating temperature range: 20°C to 33°CStorage temperature range: -25°C to 60°COperating Humidity range: 0-100% RHNote: Best result obtained in low convective environmentalELECTRICAL SPECIFICATIONS:Electrical Supply: 230V ± 10%Power consumption with Heater at max. output}: 750WPower consumption with Heater, Photo therapy andobservation lamp ON}: 1250WHEATER:Single element CE approved ceramic heater placed in aparabolic reflector.Heater output control range in manual mode: 0 to 100%PHOTOTHERAPY UNIT:Supply to each tamp: 12 V, 50 WIrradiance: 6-8 μW/cm2/nm at bed levelSUCTION CONTROL:Maximum suction: 200 mm of HgVacuum gauge range: 0-760 mm of HgOBSERVATION LIGHT:Power required: 12 V, 50 WELECTRONICS:Micro computerized systemAUXILIARY OXYGEN OUTLET:Oxygen flow control: 1-15 liter/minuteMaximum airway pressure: 55 cm water columnELECTRICAL SAFETY:As per IEC 60601-1-2 for medical equipmentsSKIN TEMPERATURE PROBE:Range: 28°C to 38°CAccuracy: +/-0.2°C within rangeResolution: 0.1°CProbe interchangeability: +/-0.2°C (Servo)

    TRANSPORT INCUBATOR
    Product Code - KS000593

    Be it inter or intra hospital transfer, proper transportation is crucial from the time infant is picked u....

    Add To Enquiry Download Catalogue View Detail

    Description & Specification

    TRANSPORT INCUBATOR

    Be it inter or intra hospital transfer, proper transportation is crucial from the time infant is picked up till reaching the destination.